Dahua Technology ARC2016C-V3 alarm controller

Technical Specification

Features:
  • Make: Dahua Technology
  • Model code: ARC2016C-V3
  • Control Panels & Accessories: Yes
  • Remote Keypad: LCD
  • Max No of RKPs: 32 keypads
Read more
Additional info:

16-channel local alarm input (expandable to 80 channels); supports NO/NC detector, detector tamper, short circuit and mask alarm 4 channel alarm outputs (expandable to 80 channels), along with forced start/shutdown, auto control, and alarm linkage Multiple zone types, such as instant zone, delayed zone, and 24-hour silent zone Alarm input/output port circuit protection Supports fault alarms, including controller tamper alarm, keypad tamper alarm, power failure alarm, battery failure alarm, battery under-voltage alarm, PSTN offline alarm, network disconnection alarm, IP conflict alarm, and MAC conflict alarm 2-channel RS-485 ports; up to 32-channel keypads; printer connection Emergency alarms, such as fire, medical and duress alarm CID (Contact ID Protocol); reuses landline telephone port (personal call requires customized PSTN hardware module) Configuration method includes keypad and web; quick configuration guide; remote configuration and search Up to 8 subsystems; single zone and subsystem arming/disarming; arming/disarming with keypad, IC card and other methods Supports 3 alarm receiving centre at the same time, supports 3 different alarm reporting strategies High-volume log search function Remote update Multiple device recovery methods Two Ethernet ports and two wired alarm centres

Read more
Make Dahua Technology
Manufacturer Dahua Technology Ltd
Category Intruder Alarms>Intruder alarm system control panels & accessories
Model code ARC2016C-V3
Control Panels & Accessories Yes
Remote Keypad LCD
Max No of RKPs 32 keypads
Tamper Yes
No Event Logs 20,000 event logs
No of Zones 1
Keypad Operated Yes
Physical Specifications Dimensions mm: 275 x 75 x 275
Environmental Specifications Operating Temp oC: -10 ~ 55 C (14 ~ 131 F)
Additional info
  • 16-channel local alarm input (expandable to 80 channels); supports NO/NC detector, detector tamper, short circuit and mask alarm
  • 4 channel alarm outputs (expandable to 80 channels), along with forced start/shutdown, auto control, and alarm linkage
  • Multiple zone types, such as instant zone, delayed zone, and 24-hour silent zone
  • Alarm input/output port circuit protection
  • Supports fault alarms, including controller tamper alarm, keypad tamper alarm, power failure alarm, battery failure alarm, battery under-voltage alarm, PSTN offline alarm, network disconnection alarm, IP conflict alarm, and MAC conflict alarm
  • 2-channel RS-485 ports; up to 32-channel keypads; printer connection
  • Emergency alarms, such as fire, medical and duress alarm
  • CID (Contact ID Protocol); reuses landline telephone port (personal call requires customized PSTN hardware module)
  • Configuration method includes keypad and web; quick configuration guide; remote configuration and search
  • Up to 8 subsystems; single zone and subsystem arming/disarming; arming/disarming with keypad, IC card and other methods
  • Supports 3 alarm receiving centre at the same time, supports 3 different alarm reporting strategies
  • High-volume log search function
  • Remote update
  • Multiple device recovery methods
  • Two Ethernet ports and two wired alarm centres
Download PDF version Download PDF version

Related Whitepapers

Enhanced Ethernet Technology (ePoE)

HDCVI 3.0: Re-Empowering The Analogue Coax Infrastructure For Intelligent UHD Video

Security investments retailers should consider for their 2021 budget

Quick poll