Bosch MIC440AXWUA14636P 36x optical zoom 470 TVL camera

Technical Specification

Features:
  • Make: Bosch
  • Model code: MIC440AXWUA14636P
  • Chip Inch Size ": 1/4 inch
  • Colour Type: Colour / Monochrome
  • Resolution TVL: 470
Read more
Additional info:

The MIC Series 440 explosion-protected camera has been designed to offer an extremely reliable, robust, and high quality surveillance solution for potentially volatile security applications that demand the very best performance. Precision engineered to exacting standards, the range meets the requirements of ATEX Directive 94/9/EC Exd IIC T6 and CSA Class I, Division 1, Groups CD, Class II, Division 1, Groups EFG, T6 for safe use in explosive atmospheres such as those found in oil, gas, chemical processing sites, and petrochemical refineries.

Read more
Make Bosch
Manufacturer Bosch Security Systems
Category CCTV>CCTV cameras
Model code MIC440AXWUA14636P
Chip Inch Size " 1/4 inch
Colour Type Colour / Monochrome
Resolution TVL 470
Digital (DSP) Yes
Specialist Types Infrared
Auto Iris Yes
Sensitivity lux 0.01
Direct Drive Yes
Electrical Specifications Voltage: 18 V AC
Power Consumption: 25.2 W
Motion Activated Yes
High Speed Yes
Focal Length mm 3.4 ~ 122.4
Wide Dynamic Range Yes
Picture Elements HxV 440
Back Light Compensation Yes
Auto Gain Control Yes
White Balance Yes
Electronic Shutter range 1/1 to 1/10,000 s
S/ N (Signal/ Noise) Ratio dB > 50
Synchronisation Internal / External (V?Lock)
Signal Mode PAL
Zoom Yes
Physical Specifications Dimension mm: 286 x 523.6 x 189
Weight g: 1,5500
Environmental Specifications Operating Temperature oC: -20 ~ +60 C (-4 ~ +140 F)
Protection: IP68
Additional info The MIC Series 440 explosion-protected camera has been designed to offer an extremely reliable, robust, and high quality surveillance solution for potentially volatile security applications that demand the very best performance. Precision engineered to exacting standards, the range meets the requirements of ATEX Directive 94/9/EC Exd IIC T6 and CSA Class I, Division 1, Groups CD, Class II, Division 1, Groups EFG, T6 for safe use in explosive atmospheres such as those found in oil, gas, chemical processing sites, and petrochemical refineries.
Download PDF version Download PDF version

Related Whitepapers

The benefits of Edge AI + Cloud for security systems

A focus on video surveillance cybersecurity

14 success stories about how video technology is improving city life

Quick poll
What is the most significant challenge facing smart building security today?