Ring buffer for 2,000 entries. Slot for RS 485 interface (5-wire) for connection to interface converter. RS 232 interface for connecting a notebook (stand- alone solution). Connection for an external reader (magnetic, chip card or contactless readers). The ACT includes the following connections: 1 reader with LED display and 2-wire keypad, 1 door strike relay, 1 alarm relay, 1 door strike button, 1 door monitoring contact, 1 to 300 persons door release with 1) only card; 2) only PIN code; 3) card and PIN code; 4) card or PIN code, 4 access authorisations per person; time; day and door indication.
Make | Esser |
---|---|
Manufacturer | Esser |
Model code | Access Control Terminal |
Electrical Specifications | Voltage: 10 ~ 15 |
Physical Specifications | Dimensions mm: 201 x 147 x 51 |
Accessories | Evaluation Unit |
Additional info | Ring buffer for 2,000 entries. Slot for RS 485 interface (5-wire) for connection to interface converter. RS 232 interface for connecting a notebook (stand- alone solution). Connection for an external reader (magnetic, chip card or contactless readers). The ACT includes the following connections: 1 reader with LED display and 2-wire keypad, 1 door strike relay, 1 alarm relay, 1 door strike button, 1 door monitoring contact, 1 to 300 persons door release with 1) only card; 2) only PIN code; 3) card and PIN code; 4) card or PIN code, 4 access authorisations per person; time; day and door indication. |