- Make: Altronix
- Model code: eFlow102NA8V
- Input Voltage: 220 V AC
- Output Voltage: 12 V DC
- No of Outputs: 8
Altronix eFlow102NA8V unit distribute and switch power to access control systems and accessories. It converts a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into eight (8) independently controlled 12VDC fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.
Read moreMake | Altronix |
---|---|
Manufacturer | Altronix |
Category | CCTV>Power supplies & batteries |
Model code | eFlow102NA8V |
Input Voltage | 220 V AC |
Output Voltage | 12 V DC |
No of Outputs | 8 |
Power Supplies & Batteries | Yes |
Environmental Specifications |
Operating Temperature C: 0 ~ 49 C (32 ~ 120 F ) Operating Humidity %: 85 |
Physical Specifications |
Dimension mm: 305 x 394 x 114 Weight g: 3920 |
Additional info |
Altronix eFlow102NA8V unit distribute and switch power to access control systems and accessories. It converts a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into eight (8) independently controlled 12VDC fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. |
Download PDF version Download PDF version |
Palm vein recognition
DownloadThe key to unlocking K12 school safety grants
DownloadPhysical access control
Download5 surprising findings from OT vulnerability assessments
DownloadHoneywell GARD USB threat report 2024
Download