Altronix eFlow102NA8DV Access Power Controller w/ Power Supply/Charger
Technical Specification
- Make: Altronix
- Model code: eFlow102NA8DV
- Input Voltage: 220 V AC
- Output Voltage: 12 V DC
- No of Outputs: 8
eFlow102NA8DV distributes and switches power to access control systems and accessories. It converts a 220VAC 50/60Hz input into eight (8) independently controlled 12VDC PTC protected outputs. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.
Read moreMake | Altronix |
---|---|
Manufacturer | Altronix |
Category | CCTV>Power supplies & batteries |
Model code | eFlow102NA8DV |
Input Voltage | 220 V AC |
Output Voltage | 12 V DC |
No of Outputs | 8 |
Power Supplies & Batteries | Yes |
Environmental Specifications |
Operating Temperature C: 0 ~ 49 C (32 ~ 120 F ) Operating Humidity %: 85 |
Physical Specifications |
Dimension mm: 305 x 394 x 114 Weight g: 3920 |
Additional info |
eFlow102NA8DV distributes and switches power to access control systems and accessories. It converts a 220VAC 50/60Hz input into eight (8) independently controlled 12VDC PTC protected outputs. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. |