Altronix eFlow102NA8 Access Power Controller w/ Power Supply/Charger

Technical Specification

Features:
  • Make: Altronix
  • Model code: eFlow102NA8
  • Input Voltage: 120 V AC
  • Output Voltage: 12 V DC
  • No of Outputs: 8
Read more
Additional info:

eFlow102NA8 distributes and switches power to access control systems and accessories. It converts a 120VAC 60Hz input into eight (8) independently controlled 12VDC fuse protected outputs with a total of 10A continuous supply current. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Read more
Make Altronix
Manufacturer Altronix
Category CCTV>Power supplies & batteries
Model code eFlow102NA8
Input Voltage 120 V AC
Output Voltage 12 V DC
No of Outputs 8
Power Supplies & Batteries Yes
Environmental Specifications Operating Temperature C: 0 ~ 49 C (32 ~ 120 F )
Operating Humidity %: 85
Physical Specifications Dimension mm: 311 x 394 x 114
Weight g: 3920
Additional info

eFlow102NA8 distributes and switches power to access control systems and accessories. It converts a 120VAC 60Hz input into eight (8) independently controlled 12VDC fuse protected outputs with a total of 10A continuous supply current. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.