ComNet FDX2HSDM1EA/M dual high speed RS485 data transceiver
Technical Specification
- Make: ComNet
- Model code: FDX2HSDM1EA/M
- Data Transceiver: Yes
- No of Fibres: 1 in, 1 out fibres
- Dimensions mm: 104 x 94 x 28
FDX2HSDM1EA/M is a dual high speed RS485 data transceiver that meets RS485 (2W) specifications. The ComNet™ FDX2HSD(M,S)(1,2)(EA,EB)/M data transceivers is tested and certified by an independent laboratory for full compliance with the environmental requirements. The robust design of FDX2HSDM1EA/M assures extremely high reliability in unconditioned out-of-plant/roadside environments. The ComNet™ FDX2HSD(M,S)(1,2)(EA,EB)/M data transceivers are NTCIP compatible and the built-in fiber link tester allows for the testing of the fiber. The remote fault indication of FDX2HSDM1EA/M allows the user to determine when a fiber break or loss of prime operating power has occurred, or a transceiver in the field has failed.
Read moreMake | ComNet |
---|---|
Manufacturer | ComNet Europe Ltd. |
Category | CCTV>Fibre optics, telemetry receivers, transmitters, transceivers |
Model code | FDX2HSDM1EA/M |
Data Transceiver | Yes |
No of Fibres | 1 in, 1 out fibres |
Physical Specifications |
Dimensions mm: 104 x 94 x 28 Weight g: 900 |
Environmental Specifications |
Operating Temperature oC: -40 ~ +75 C (-40 ~ +167 F) Operating Humidity %: 0 ~ 95 |
Electrical Specifications |
Voltage: 8 ~ 36 V DC Power Consumption: 4 W |
Additional info |
FDX2HSDM1EA/M is a dual high speed RS485 data transceiver that meets RS485 (2W) specifications. The ComNet™ FDX2HSD(M,S)(1,2)(EA,EB)/M data transceivers is tested and certified by an independent laboratory for full compliance with the environmental requirements. The robust design of FDX2HSDM1EA/M assures extremely high reliability in unconditioned out-of-plant/roadside environments. The ComNet™ FDX2HSD(M,S)(1,2)(EA,EB)/M data transceivers are NTCIP compatible and the built-in fiber link tester allows for the testing of the fiber. The remote fault indication of FDX2HSDM1EA/M allows the user to determine when a fiber break or loss of prime operating power has occurred, or a transceiver in the field has failed. |
Download PDF version Download PDF version |
Related Whitepapers
ComNet - Designing in flexibility and controlling costs in your Ethernet network
A new alternative to video transmission over Ethernet for industrial security applications
EoVDSL: A cost-effective solution for transmitting Ethernet data over existing copper wiring for ITS and traffic applications
The 2024 state of physical access trend report
DownloadThe security challenges of data centers
DownloadSecurity practices for hotels
DownloadSIA Identity and Biometrics Symposium
DownloadGunshot detection
Download